Most wiring in a modern American home comes down to three products: non-metallic (NM) cable for dry indoor runs, underground feeder (UF) cable for wet and buried locations, and individual THHN/THWN conductors pulled through conduit where durability matters. Each is defined by the National Electrical Code (NEC) for specific environments, and using the wrong one in the wrong place is not a minor mistake — NM cable is explicitly prohibited in wet or buried locations. Here is how the three differ, and how to match them to a project.
Understanding Common Residential Electrical Wires
Non-metallic cable — sold commercially as Romex, though Romex is a registered trademark of Southwire Corporation — is the workhorse of North American residential wiring. According to Dongguan Greater Wire & Cable, an electrical cable manufacturer, NM-B cable carries two to four THHN-insulated copper conductors inside a standard PVC jacket, usually with paper or plastic fillers between them. That jacket is thinner than the one on UF-B cable and has no special moisture-proof treatment, which makes the cable lighter and easier to handle but limits where it can be installed.
The NEC treats that limitation as a hard rule. Under Article 334, as summarized by Greater Wire, NM-B wire is limited to dry locations and is prohibited in wet or damp locations, buried applications, commercial garages, special occupancies such as movie theaters, and environments above 80°C. It must also be installed where it will not be subject to physical damage. Where it is permitted — chiefly wood-frame residential construction — its lower cost relative to conduit-and-wire systems drives what US Electrical Authority describes as nearly universal adoption.
Underground feeder cable looks similar but is built for the opposite job. The NEC's Article 340, again per Greater Wire's summary, allows UF-B in various indoor and outdoor environments: it can be directly buried, subject to minimum burial depth requirements, and is suitable for damp, wet, and dry locations. Its current-carrying capacity must be corrected in accordance with NEC 310.15(B)(3)(a). Practically, that makes UF the natural choice for outdoor lighting or running power to a shed, where the cable will be exposed to moisture or soil.
THHN and THHN/THWN conductors are a different category altogether: individual insulated wires rather than a finished cable. The letters describe the wire's coating properties and temperature rating. These conductors often live inside a cable assembly such as NM-B, but they are also pulled individually through conduit, which makes them suitable for exposed or outdoor areas where the conduit, not a plastic jacket, provides the protection.
Wire gauge matters as much as cable type. Conductors are sized by the American Wire Gauge (AWG) standard, and a conductor that is too thin for its load can overheat — which is why the NEC ties ampacity to conductor size and installation conditions, requiring derating corrections such as those in 310.15(B)(3)(a) when multiple current-carrying conductors share a raceway or cable. Heavier household loads demand heavier wire, and the gauge printed on a cable's jacket should always be matched to the circuit it will serve.